Services
Cable & Wires
CABLE & Wire
A wire is a single, usually cylindrical, flexible strand or rod of metal. Wires are used to bear mechanical loads or electricity and telecommunications signals. Wire is commonly formed by drawing the metal through a hole in a die or draw plate. Wire gauges come in various standard sizes, as expressed in terms of a gauge number.
- Helukabel
- Lapp kabel
- Polycab
- Thermocable
CABLE & ACCESSORIES
Cable and wire- A cable is a group of two or more insulated conductors used for transmission of electrical power or signals. The conductor is normally classified as per the gauge number, wire number, and color and there’s lot more design depending on the intended application. The conductor needs to be used in areas that are subjected to harsh mechanical stress and insulated to offer better protection than wires..
CABLE GLAND
Cable glands are mechanical cable entry devices. They are used throughout a number of industries in conjunction with cable and wiring used in electrical instrumentation and automation systems. Cable glands may be used on all types of electrical power, control, instrumentation, data and telecommunications cables.
- Lapp kabel
- Trinity touch
- Jacob
- Flexa
CONDUIT PIPES
Electrical conduit provides very good protection to enclosed conductors from impact, moisture, and chemical vapors. Varying numbers, sizes, and types of conductors can be pulled into a conduit, which simplifies design and construction compared to multiple runs of cables or the expense of customized composite cable
- Flexa
- Helukabel
- Trinity Touch
- Lapp kabel
CABLE ENDS
Cables consist of three major components: conductors, insulation, protective jacket. The makeup of individual cables varies according to application. The construction and material are determined by three main factors.
- Schneider electric
- Trinity touch
- Lapp kabel
- Helukabel
- Klauke
- Panduit
CABLE TIES
A cable tie (also known as a wire tie, hose tie, steggel tie, or zip tie, and by the brand names Ty-Rap) is a type of fastener, for holding items together, primarily electrical cables or wires. Because of their low cost and ease of use, cable ties are ubiquitous, finding use in a wide range of other applications. Stainless steel versions, either naked or coated with a rugged plastic, cater for exterior applications and hazardous environments.
- Panduit
- Surelock
- Hellermann tytlon
Automation
Automation
Automation is the technology by which a process or procedure is performed with minimal human assistance.[1] Automation [2] or automatic control is the use of various control systems for operating equipment such as machinery, processes in factories, boilers and heat treating ovens, switching on telephone networks, steering and stabilization of ships, aircraft and other applications and vehicles with minimal or reduced human intervention.
CONTACTORS
contactor is an electrically-controlled switch used for switching an electrical power circuit.[1] A contactor is typically controlled by a circuit which has a much lower power level than the switched circuit, such as a 24-volt coil electromagnet controlling a 230-volt motor switch.
- Schneider electric
- Abl sursum
OVERLOAD RELAYS
A relay is an electrically operated switch. Many relays use an electromagnet to mechanically operate a switch, but other operating principles are also used, such as solid-state relays. Relays are used where it is necessary to control a circuit by a separate low-power signal, or where several circuits must be controlled by one signal.
- Schneider electric
- Abl sursum
- Siemens
MANUAL CHANGEOVER
changeover is the process of converting a line or machine from running one product to another. Changeover times can last from a few minutes to as much as several weeks in the case of automobile manufacturers retooling for new models. The terms set-up and changeover are sometimes used interchangeably however this usage is incorrect.
- Schneider electric
- Abl sursum
AUTOMATIC CHANGEOVER
A transfer switch is an electrical switch that switches a load between two sources. Some transfer switches are manual, in that an operator effects the transfer by throwing a switch, while others are automatic and trigger when they sense one of the sources has lost or gained power.
- Schneider electric
- Abl sursum
- Havells
ACB
A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by excess current from an overload or short circuit. Its basic function is to interrupt current flow after a fault is detected. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation.
- Schneider electric
- L & T
Other Services
PLUG & SOCKETS
The insertion of a plug into a drainage outlet allows the container to be filled with water or other fluids. In contrast to screw on caps, plugs are pushed into the hole and are not put over the hole.
- Schneider electric
- ABL Sursum
GROUNDING BRAIDS
A braid (also referred to as a plait) is a complex structure or pattern formed by interlacing three or more strands of flexible material such as textile yarns, wire, or hair.[1] The materials used have depended on the indigenous plants and animals available in the local area They have been made for thousands of years,[2] in many different cultures around the world, for a variety of uses.
- All sizes of earthing strips/braids
PLUG DRAINS
If more than one plumbing fixture is clogged then electric drain cleaners, battery powered drain cleaners, sewer jetters or such mechanical devices are usually required to clear obstructions along the entire length of the drain piping system, that is, from fixture drain inlets through the main building drains and lateral piping outside the building to the collector sewer mains.
- Poeppelmann GMBH
HEAT SHRINK TUBE
Heat-shrink tubing (or, commonly, heat shrink or heatshrink) is a shrinkable plastic tube used to insulate wires, providing abrasion resistance and environmental protection for stranded and solid wire conductors, connections, joints and terminals in electrical work
- Lapp
- Cellpack
- 3M
CABLE TRAYS
In the electrical wiring of buildings, a cable tray system is used to support insulated electrical cables used for power distribution, control, and communication. Cable trays are used as an alternative to open wiring or electrical conduit systems, and are commonly used for cable management in commercial and industrial construction.
- All sizes of cable trays
TAPE & ADHESIVE
Adhesive tape refers to any one of a variety of combinations of backing materials coated with an adhesive. Different backing materials and adhesives can be used depending on the intended use.
Adhesive tapes consist of a material called a backing or carrier (paper, plastic film, cloth, foam, foil, etc.), which is coated with an adhesive and a release liner if needed.
- 3M
- Flexa
Aviation Light
Day Marking Spheres
We offer superior quality safety marking sphere and conductor marking sphere that provides accurate result for identification of wires and their capacitance. Light in weight, these spheres are moulded in glass fiber reinforced polyester resin that ensures longer service life.Overview
“TECHNOVATORS” ADMS-600 & ADMS-400 DAY marking spheres are coloured mechanical devices used for the identification of wires across electricity pylons, & cable cars. “Warning against Cable & Wires in Flight path.”- Conforms to ICAO & FAA regulations.
- Very light but strong moulded in Glass fiber reinforced polyester resin.
- Aluminium alloy clamps to match the exact size the wire.
- Available in Two halves for easy fixing on existing installations.
- UV stabilized colours dissolved in resin used while moulding, ensures against color fading.
- Polyurethane over coat increases color fastness and longer life.
- Drain holes are provided for exist of rain water.
- Available in completely Red / Orange or White colour.
Applications
- High-rise Power transmission Lines
- High slung Cable-car lines
- Ropeway cables
- Guy Wires
Installation
- Designed for cable mountings through machined to size clamps.
- Installation convenience also ensured because of split-design (available in two halves)
Technical DetailsModel No.Input VoltageLamp TypeLight Intensity against various Background IlluminancesEnvironment Protection ClassPhoto controller> 500 cd m250-500 cd m2< 50 cd m2For LightFor Control GearTASS-HI-XE-D-N230V ACFlash Tube200,000 ± 25% cd20,000 ± 25% cd2000 ± 25% cdIP 65IP 65External with extended cordElectrical SpecificationsInput Voltage230V AC 50 HzPhysical CharacteristicsEnclosure MaterialStainless steel – Grade 304 1.6mmLight Window MaterialToughened GlassInterlocking Safety LatchProvidedCable Entry ThroughDouble Compression plated Brass GlandsLamp SpecificationsType of LampXenon LampMin/Max Voltage1200V /2400VTypical Voltage1450VEnergy/Flash330 J Max – 210J NominalMax/Avg Power Watts220 max – 140 nominalTrigger Cap0.4 µfTrigger Voltage15 Kv NominalTrigger TypeWire WrapEnvelope MaterialQuartzLamp Life8000 hrs. at 142 JEnvelope Size6 mmPhotometric DataColour of LightWhiteVertical Beam Spread3-7 °Horizontal Beam Spread120 °Flash SynchronizationUpto 24 Lights on one structureFlash RateBetween 40 & 60 Flashes per MinuteShipping details for medium intensity white flashing obstruction lights
Carton No. Carton Description Net Weight (KG) Gross Weight (KG) Dimn. Vol. CBM 1 HI-LIGHT 18 31 640x535x460 0.1575 2 Control Panel 20 45 740x610x445 0.21 3 Master Controller 6 9 540x390x315 0.066
Low Intensity Twin Obstruction Warning Light
Our Low Intensity Twin Light is designed for the safety of aviation by marking high rise structures and buildings. The multiple lights serve as a reliable warning system by reducing the possibility of complete blackout, due to the failure of one source.Overview
- ICAO (Type A & B) compliant product design and performace
- Omnidirectional RED light source (10 cd – 32 cd)) hence no requirement of filters that fade quickly
- Customizable for both AC and DC conditions
- Multiple light elements in the source reduce complete blackout possibility due to a single source failure
- High quality optics for excellent beam spread control.
- Light weight sturdy casings (of high quality pressed FRP)
- All hardware of Tower marker obstruction lights are made of corrosion resistant metals.
- Excellent dust and moisture sealing through improved gaskets
- Bird spikes for protection against droppings
Technical Specifications
- Temperatures ranging from (-20°C to +55°C).
- Will withstand wind in excess of 150 mph (240 kph), (150 knots)
- Fog, Rain
- Humidity : 80%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Photometric Data |
|
Night Mode |
Red |
Vertical Beam Spread |
> 10 ° |
Horizontal Coverage |
360 ° |
“Ground Scatter Light” cut-off angle |
-5 ° |
Electrical Specifications Tower Marker Obstruction Lights Model : TASS-LI INTG |
|||||||||||
Input Supply |
Operating Voltage |
System Operating on DC Volts |
Current (Amp.) |
Volt Amps (VA) |
Watts
(V x I) |
||||||
Min |
Max |
Min |
Max |
Min |
Max |
||||||
230 V AC with SMPS Supply
(50 Hz) |
110 V AC
(60 Hz) |
240 V AC
(50 Hz) |
12 V | 300 mA | 500 mA | 3.6 | 6 | 6 | |||
24 V | 150 mA | 250 mA | 3.6 | 6 | 6 | ||||||
48 V | 75 mA | 125 mA | 3.6 | 6 | 6 | ||||||
230 V AC (50 Hz) |
110 V AC
(60 Hz) |
240 V AC
(50 Hz) |
12 V | 300 mA | 500 mA | 3.6 | 6 | 6 | |||
24 V | 150 mA | 250 mA | 3.6 | 6 | 6 | ||||||
48 V | 75 mA | 125 mA | 3.6 | 6 | 6 |
Light Characteristics |
|
Body Material |
Compression Molded Glass Fiber reinforced Polyester |
Lense Material |
Polished Acrylic |
Height (mm/inches) |
225 mm |
Width (mm/inches) |
160 ± 5 mm |
Mass (Kg/lbs) |
5 Kg Approx. |
Construction of Tower Marking Obstruction Lights |
|
Lens Material |
Polished Acrylic |
Sealing |
EPDM Gasket |
Weight |
6 Kg Approx. |
Environmental and Electrical |
|
Temperature Range |
– 20 ° C to + 55 ° C |
Waterproof |
Through improvised Gaskets and Sealant |
Environment Protection Standard for Light |
IP 65 Standard |
Environment Protection Standard for Control Panel |
IP 55 Standard |
ICAO Type |
Type “A” |
Light Source |
LED Cluster |
Light Color |
RED |
Intensity |
> 10 cd |
Horizontal Divergence |
360 ° |
Lamp Life |
> 1,00,000 hrs approx. |
Radial Emission |
As per CISPR 11 |
Shipping Specifications
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | Low intensity twin light | 13 | 24 | 550x380x450 | 0.094 |
Low Intensity Neon Obstruction Warning Light
We offer a range of highly energy efficient Neon Obstruction Lights to mark high rise buildings, bridges, towers etc. The light uses cold cathode to produce low intensity incandescent light. These lights are low in maintenance and are best suited for high vibration area.Overview
- ICAO (Type A & B) compliant product design and performance
- Omni directional RED Neon light source (10 cd – 32 cd)) hence no requirement of filters that fade quickly
- Customizable for both AC and DC conditions
- High quality optics for excellent beam spread control.
- Light weight sturdy casings (of high quality die-cast aluminum)
- All hardware of Tower marker obstruction lights are made of corrosion resistant metals.
- ICAO (Low Intensity Type ‘A’ & ‘B’ compliant product design and performance.
- Omni-directional RED light source hence no requirement of filters.
- Borosilicate glass dome.
- Aluminium Alloy housing.
- Excellent dust and moisture sealing.
- Wide operating temperature range (-20 ºC to +55 ºC)
Technical Specifications
Operating Conditions- Will withstand wind in excess of 150 mph (240 kph), (150 knots)
- Fog, Rain
- Humidity :90%
- Electromagnetic Interference Shielded
- Radio Frequency Interference Shielded
Photometric DataNight ModeRedHorizontal Coverage360 °Flash RateStationery ModeElectrical SpecificationsInput SupplySystem Operating on DC VoltsCurrent (Amp)Min.Max.12V DC1800 V0.75A1.5A230V AC1800 V0.75A12V DCLight CharacteristicsICAO TypeType “A”Light SourceNeon LampLight ColorREDIntensity10 to 32 cdHorizontal Divergence360 °Lamp Life20,000 hrs approx.Radial EmissionAs per CISPR 11ConstructionLens MaterialBorosilicate GlassSealingSilicon SealantWeight1.250 Kg Approx.Environmental and ElectricalTemperature Range– 40 ° C to + 50 ° CWaterproofThrough EPDM Gasket and SealantEnvironment Protection Standard for LightIP 65 StandardEnvironment Protection Standard for Control PanelIP 55 StandardShipping details for solar powered obstruction lightsCarton No. Carton Description Net Weight (KG) Gross Weight (KG) Dimn. Vol. CBM 1 Neon Lamp 2 Solar Module 8 12 755 x 645 x 190 0.092 3 Battery with Charge Controller 50 65 4 Mounting 32 38 5 Cable 4 5
Low Intensity Obstruction
Warning Light
AVAIDS tower warning lights are compact,sturdy,power saving LED low intensity lights available with optional advanced feature.Key Features
|
Solar Powered Medium Intensity Obstruction Warning Light
We offer Hi-Tech Solar Powered Obstruction Lights for multiple applications ranging from marine lighting to emergency phone booth lighting and airport security markers for parked planes. They are very compact and easy-to-use with low maintenance due to negligible wear and tear.
Overview
|
|
|
|
- Temperatures ranging from -20°C to 55°C.
- Will withstand wind in excess of 150 mph (240 kph), (150 knots)
- Fog, Rain
- Humidity : 100%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Solar Panels |
|
Type |
Mono/Poly Crystalline |
Maximum Power |
10 TO 120 Watt |
Efficiency |
90 % |
Battery |
|
Type |
Sealed Maintenance Free |
Nominal Voltage |
12 /24 V |
Capacity |
Depending upon Load & Design Autonomy |
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | TASS-LI-INTG | 3 | 5 | 170 x 160 x 330 | 0.0089 |
2 | Solar Module | 30 | 56 | 1370 x 550 x 785 | 0.059 |
3 | Battery with Battery Box | 40 | 50 | 700 x 500 x 600 | 0.21 |
4 | Mounting | 68 | 88 | 1485 x 400 x 320 | 0.019 |
5 | Cable | Depends upon site location |
Medium Intensity Obstruction Warning Light
Medium Intensity obstacle lights may be used where the object is an extensive one or its height above the level of the surrounding ground is greater than 45m.Features
|
- High rise buildings.
- Towers and telecom structures.
Technical Details |
|||||||||||||||||||
Catalogue No. |
Colour Of Light Emitted |
ICAO Type |
Lamp Type |
Optical Lens Material |
Weight |
Environment Protection Class |
Photocontroller Built-in Type |
Radiated Emission As Per CISPR 11 |
Light Intensity |
||||||||||
For Light |
For Control Gear |
||||||||||||||||||
TASS-MI-
XLL |
Red |
Type B/C |
LED Crusher |
Borosilicate Glass |
8.5 kg Approx. |
IP 65 |
IP 65 |
External |
Satisfactory |
2000 cd
± 25% |
Medium Intensity Twin Obstruction Warning Light
We offer premium quality Led – Medium Intensity (Twin Light) that are used as tower warning lights. These high power Omni-directional lights are energy efficient and are ideal for use with solar powered system.Overview
TECHNOVATORS” Medium Intensity Flashing RED aviation warning light. “Long life solution for marking of tall structures”
|
- Temperatures ranging from -20°C to +55°C
- Will withstand wind in excess of 150 mph (240 kph), (150 knots)
- Fog, Rain
- Humidity : 80%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Photometric Data |
|
Night Mode |
Red |
Vertical Beam Spread |
> 3 ° |
Horizontal Coverage |
360 ° |
“Ground Scatter Light” cut-off angle |
-5 ° |
Flash Rate |
20 – 60 FPM |
Electrical Specifications |
||||||||
Input Supply |
Operating Voltage |
System Operating on DC Volts |
Current (Amp) |
Volt Amps (VA) |
Watts
(V x I) |
|||
Min |
Max |
Min |
Max |
Min |
Max |
|||
220V AC with SMPS Supply |
175 V
AC |
275 V
AC |
12 V |
8 | 10 | 96 | 120 | 120 |
24 V | 4 | 5 | 96 | 120 | 120 | |||
48 V | 2 | 2.5 | 96 | 120 | 120 | |||
220VAC (50Hz) |
175 V
AC |
275 V
AC |
12 V | 8 | 10 | 96 | 120 | 120 |
24 V | 4 | 5 | 96 | 120 | 120 | |||
48 V | 2 | 2.5 | 96 | 120 | 120 |
Light Characteristics |
|
ICAO Type |
Type “B/C” |
Light Source |
LED Cluster |
Light Color |
RED |
Intensity |
> -2000 cd |
Horizontal Divergence |
360 ° |
Lamp Life |
> 1,00,000 hrs |
Radial Emission |
As per CISPR 11 |
Physical Characteristics |
|
Body Material |
Cast Aluminium |
Lens Material |
Polished Acrylic |
Mounting |
Hot Dip Galvanized Structure |
Height (mm/inches) |
544 mm |
Width (mm/inches) |
395 mm |
Mass (Kg/lbs) |
13.850 Kg Approx. |
Operation |
|
Minimum Autonomy |
24 hrs. |
Latitude Range |
1000 meter |
On/Off Level |
Automatic |
Illumination Technology |
Photons generation with LED conduction |
Lifespan of LEDs |
> 1,00,000 hrs. Approx. |
Available Flash Patterns |
20 – 60 FPM |
Color Technology of LED |
Red Light Emitting Diode |
Environmental and Electrical |
|
Temperature Range |
– 20 ° C to + 50 ° C |
Waterproof |
Through EPDM Gasket and Sealant |
Environment Protection Standard for Light |
IP 65 Standard |
Environment Protection Standard for Control Panel |
IP 55 Standard |
Technical Details |
||||
Cat No. |
Weight |
Dimensions |
Body Color |
Character |
TASS – MI – Duplex |
23.590Kg Approx. |
Height : 740mm
Diameter : 394 mm |
White / Optionally
RED |
Flashing 20 to 60 Flash/min (Flash rate adjustable) |
Operational Voltage |
Color of Light Emitted |
||
12 V DC, 24 V DC, 48 V DC, 230 V AC |
RED |
Twin MI Obstruction Light Dimension Detail |
Twin Obstruction Light Mounting Detail |
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | TASS-MI-DUPLEX | 26 | 36 | 450x440x840 | 0.166 |
2 | Control Panel | 14 | 20 | 550x465x255 | 0.065 |
Medium Intensity White flashing Obstruction Warning Light
Medium Intensity White Flashing lights are used for the marking of structures and buildings for Day as Well as Night Marking. These lights can be operated through a reliable Switch Mode Power Supply, with in-built photo-sensing device.Overview
|
- Temperatures ranging from -20°C to +55°C
- Will withstand wind in excess of 150 mph (240 kph), (150 knots)
- Fog, Rain
- Humidity : 80%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Photometric Data |
|
Night Mode |
White |
Vertical Beam Spread |
> 3 ° |
Horizontal Coverage |
360 ° |
“Ground Scatter Light” cut-off angle |
-5 ° |
Flash Rate |
20 – 60 FPM |
Light Characteristics |
|
ICAO Type |
Type “B/C” |
Light Source |
Xenon Tube |
Light Color |
White |
Effective Intensity Cd at given Background Luminance |
Above 500 cd/m2
20,000 ± 25%
Below 50 CD/m2
2000 CD ± 25% |
Horizontal Divergence |
360 ° |
Radial Emission |
As per CISPR 11 |
Lamp Life |
— |
Physical Characteristics |
|
Body Material |
Cast Aluminium |
Lens Material |
Polished Acrylic |
Height (mm/inches) |
415 |
Width (mm/inches) |
333 |
Mass (Kg/lbs) |
18.230 Kg |
Operation |
|
Minimum Autonomy |
24 hrs |
Latitude Range |
150 meters |
On/Off Level |
Automatic |
Illumination Technology |
Flash generation with Xenon |
Lifespan of Xenon Flashtube |
> 2 years |
Available Flash Patterns |
20 – 60 FPM |
Environmental and Electrical |
|
Temperature Range |
– 20 ° C to + 55 ° C |
Waterproof |
Through EPDM Gasket and Sealant |
Environment Protection Standard for Light |
IP 65 Standard |
Environment Protection Standard for Control Panel |
IP 55 Standard |
Obstruction Light Dimension Detail |
Obstruction Light Mounting Detail |
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | TASS-MI-XE-D-N | 21 | 35 | 525x525x465 | 0.128 |
2 | Control Panel | 29.6 | 49 | 550x410x470 | 0.106 |
Medium Intensity Red & White Flashing Obstruction Warning Light
This Medium Intensity light uses combination of both red and white light for identification of tall buildings. Sturdy to withstand extreme weather conditions, the Medium Intensity lights are housed in Cast Aluminium Alloy with Polyurethane coating for all weather protection and humidity resistance.Overview
|
- Temperatures ranging from -20° C to +55° C).
- Will withstand wind in excess of 150 mph (240 kph)
- Fog, Rain
- Humidity : 80%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Photometric Data |
|
Night Mode |
Red |
Vertical Beam Spread |
> 3 ° |
Horizontal Coverage |
360 ° |
“Ground Scatter Light” cut-off angle |
< 3% light output -5 ° vertical |
Flash Rate |
20 – 60 FPM |
Light Characteristics |
|
ICAO Type |
Type “B/C” |
Light Source |
Xenon Lamp |
Light Color |
White |
Effective Intensity Cd at given Background Luminance |
Above 500 cd/m2
20,000 ± 25%
Below 50 CD/m2
2000 CD ± 25% |
Horizontal Divergence |
360 ° |
Lamp Life |
> 2 Years |
Radial Emission |
As per CISPR 11 |
Physical Characteristics |
|
Body Material |
Cast Aluminium |
Lens Material |
Polished Acrylic |
Mounting |
— |
Height (mm/inches) |
645.5 |
Width (mm/inches) |
400 |
Mass (Kg/lbs) |
24 approx. |
Intensity |
200000 CD for day time |
Operation |
|
Minimum Autonomy |
— |
Latitude Range |
— |
On/Off Level |
— |
Illumination Technology |
??? |
Lifespan of Xenon Tube |
— |
Available Flash Patterns |
20 – 60 FPM |
Color Technology of LED |
??? |
Environmental and Electrical |
|
Temperature Range |
– 40 ° C to + 50 ° C |
Waterproof |
Through EPDM Gasket and Sealant |
Environment Protection Standard for Light |
IP 65 Standard |
Environment Protection Standard for Control Panel |
IP 55 Standard |
Red & White FlashingObstruction Light Dimension Detail |
Red & White Flashing Obstruction Light Mounting Detail |
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | TASS-MI-XE-D-N R&W | 21 | 35 | 525 X 525 X 465 | 0.128 |
2 | Control Panel | 29.6 | 49 | 550 X 410 X 470 | 0.106 |
Medium intensity obstruction warning light (GPS Synchronized)
UNDER CONSTRUCTION
High Intensity Obstruction Marking Lights
Our range of High Intensity Obstruction Marking Lights are unidirectional lights that are specifically designed to provide 120º horizontal with narrow-vertical beam pattern. These high intensity lights provide minimum dissipation of light with a strong focus. The beam angle and direction can easily be changed for marking high rise buildings and structures.Overview
|
- Temperatures ranging from -20°C to +55°C.
- Will withstand wind in excess of 150 mph (240 kph)
- Fog, Rain
- Humidity : upto 95%
- Does not create Electromagnetic Interference
- Does not create Radio Frequency Interference
Technical Details |
||||||||
Model No. |
Input Voltage |
Lamp Type |
Light Intensity against various Background Illuminances |
Environment Protection Class |
Photo controller |
|||
> 500 cd m2 |
50-500 cd m2 |
< 50 cd m2 |
For Light |
For Control Gear |
||||
TASS-HI-XE-D-N |
230V AC |
Flash Tube |
200,000 ± 25% cd |
20,000 ± 25% cd |
2000 ± 25% cd |
IP 65 |
IP 65 |
External with extended cord |
Electrical Specifications |
|
Input Voltage |
230V AC 50 Hz |
Physical Characteristics |
|
Enclosure Material |
Stainless steel – Grade 304 1.6mm |
Light Window Material |
Toughened Glass |
Interlocking Safety Latch |
Provided |
Cable Entry Through |
Double Compression plated Brass Glands |
Lamp Specifications |
|
Type of Lamp |
Xenon Lamp |
Min/Max Voltage |
1200V /2400V |
Typical Voltage |
1450V |
Energy/Flash |
330 J Max – 210J Nominal |
Max/Avg Power Watts |
220 max – 140 nominal |
Trigger Cap |
0.4 µf |
Trigger Voltage |
15 Kv Nominal |
Trigger Type |
Wire Wrap |
Envelope Material |
Quartz |
Lamp Life |
8000 hrs. at 142 J |
Envelope Size |
6 mm |
Photometric Data |
|
Colour of Light |
White |
Vertical Beam Spread |
3-7 ° |
Horizontal Beam Spread |
120 ° |
Flash Synchronization |
Upto 24 Lights on one structure |
Flash Rate |
Between 40 & 60 Flashes per Minute |
Carton No. | Carton Description | Net Weight (KG) | Gross Weight (KG) | Dimn. | Vol. CBM |
1 | HI-LIGHT | 18 | 31 | 640x535x460 | 0.1575 |
2 | Control Panel | 20 | 45 | 740x610x445 | 0.21 |
3 | Master Controller | 6 | 9 | 540x390x315 | 0.066 |
Low Intensity Obstruction Warning Light
AVAIDS tower warning lights are compact,sturdy,power saving LED low intensity lights available with optional advanced feature.Key Features
- ICAO (Type A/B) compliant product design and performance.
- Omni directional low intensity light (> 32 cd).
- Aviation RED light source,hence no requirement of filters that face quickly.
- Extremely energy efficient system.
- LED light source with a life exceeding 50,000 hours.
- Designed to operate under hard climatic conditions.
- Customizable for both AC and DC environments.
- Wide operating temperature range (-20 deg. Celsius to +55 deg. Celsius).
- High quality optics for excellent beam control.
- Light weight sturdy casings (of high quality FRP)
- All hardware made of stainless steel/ corrosion resistant metals.
- Excellent dust and moisture sealing .
- Humidity:95%
- Maximum Power Ratings 3 watts.
Technical Details |
|||||||||||
Catalogue No. | Colour Of Light Emitted | ICAO Type | Lamp Type | Optical Lens Material | Weight | Environment Protection Class | Type Of Control Gear | Photocontroller | Operational Voltage | Radiated Emission As Per CISPR 11 | |
TASS-LI- INTG-I | Red | Type A/B | LED | Polycarbonate | 1.2 Kg Approx. | IP 65 | Voltage Regulator | Built-in | Optional: 12, 24, 48, V DC 230±10% AC 50 Hz | Within Permissible Limits |